Glass structural silicone sealant

,

Bonding structural silicone sealant

,

Commercial double glazing silicone sealant

Product Name:
398 Silicone Structural Sealant
Tensile Adhesion Strength:
0.95 MPa(23℃)
Elongation At Maximum Strength:
145%
Adhesion Failure Area:
0%
Shore A Hardness:
42
Sag:
0 Mm
Tack-Free Time:
0.5 H
Application:
Structural Bonding For Glass Curtain Walls, Aluminum Curtain Walls And Metal Structures
Product Description

Glass Curtain Wall Sealant: How to Achieve Strong Structural Bonding in Commercial Building Facades
 
Problem | Why Is “Strong Adhesion” Alone Not Enough for Structural Assembly?
 
Commercial building facades often combine large glass surfaces, different panel dimensions, and complex curtain wall configurations. A glass curtain wall sealant used for structural assembly must create a continuous bond between glass and framing components such as aluminum profiles while transferring wind loads from the glass to the supporting curtain wall system.
“Strong adhesion” should not be evaluated through initial tack or a simple manual pull test. After structural assembly, bonded joints are exposed to wind pressure, temperature variation, and relative movement between glass and aluminum. Insufficient bond strength, inadequate bonding area, or contaminated interfaces can create localized stress and increase the risk of adhesion failure.
 
Cause | What Causes Bonding Problems in Structural Glazing Assembly?
 
The first factor is the bonding interface. Dust, oil, and aluminum surface finishes can influence the actual adhesion between structural silicone and the substrate. Coated glass, anodized aluminum, and other surface-treated materials should therefore be evaluated using the actual project substrates rather than material names alone.
The second factor is joint design. Different facade zones may experience different design wind loads. If structural bite and bonding depth are not determined according to glass dimensions, wind loads, and joint configuration, excessive stress may be concentrated in part of the bonded area.
Strong structural bonding therefore depends on the combination of tensile adhesion strength, elongation behavior, interface performance, and engineered joint dimensions.
 
Solution | Use 0.95 MPa Adhesion Data as a Measurable Selection Reference
 
398 Silicone Structural Sealant uses a one-component, neutral-cure system and is suitable for glass curtain walls, aluminum curtain walls, and various metal structural applications.
According to the supplied technical data, tensile adhesion strength at 23°C reaches 0.95 MPa, compared with a requirement of ≥0.60 MPa. Elongation at maximum strength reaches 145%, compared with a requirement of ≥100%, while the recorded adhesion failure area is 0%.
The 0.95 MPa value provides measurable evidence of adhesion performance under the specified test conditions, while 145% describes deformation behavior as the material reaches maximum tensile strength.
For commercial facade projects, actual glass, aluminum profiles, and surface coatings should still undergo adhesion and compatibility testing. Structural bonding dimensions must also be engineered according to project-specific glass dimensions and design wind loads rather than derived directly from laboratory tensile strength.
 
Technical Specifications
 

Property

Requirement

Typical Result

Cure Type

Neutral Cure

Neutral Cure

Components

One Component

One Component

Tensile Adhesion Strength at 23°C

≥0.60 MPa

0.95 MPa

Elongation at Maximum Strength

≥100%

145%

Adhesion Failure Area

≤5%

0%

Shore A Hardness

20–60

42

Sag

≤3 mm

0 mm

Tack-Free Time

≤3 h

0.5 h

Extrusion Rate

≥120 mL/min

≥490 mL/min

 
 
How It Works | How Does Glass Curtain Wall Sealant Work in Structural Assembly?
 
After curing, structural silicone forms a continuous bonding layer between the glass and aluminum frame. When wind pressure acts on the facade, loads from the glass are transferred through the structural silicone bond to the aluminum framing and then to the supporting building structure.
During this process, the 0.95 MPa tensile adhesion strength and 145% elongation at maximum strength should be evaluated together. The first represents structural adhesion under specified test conditions, while the second describes tensile deformation behavior. The recorded 0% adhesion failure area provides additional information about interface performance under the corresponding test conditions.
A measured sag of 0 mm also helps the sealant remain in the designed position during structural assembly. However, “suitable for structural glazing” does not mean that any joint dimension can be used. Final structural performance must be verified according to glass dimensions, design wind loads, structural bite, actual substrate testing, and project-specific engineering requirements.