logo

Construction Clear Polyurethane Sealant For Existing Joint Resealing

Place of Origin: China
Brand Name: YT
Certification: ISO9001, Work safety standardization certificate
Model Number: Polyurethane Construction Sealant
Minimum Order Quantity: 50 metric tons
Price: Custom Product Production
Delivery Time: Customized production depends on the situation.
Payment Terms: L/C, D/A, D/P, T/T, Western Union
Supply Ability: Custom Product Production
Inquiry Now
Get A Quote
Specifications
Highlight Features

Construction Polyurethane

,

Joint Resealing clear polyurethane sealant

,

Construction clear polyurethane sealant

Product Name:
Polyurethane Construction Sealant
Material System:
Polyurethane / PU
Components:
One-Component
Curing Method:
Moisture-Curing At Room Temperature
Elastic Recovery:
≥80%
Joint Width:
8–35 Mm; Detailed Design Requires Confirmation
Packaging:
600 ML Foil Sausage
Application:
Construction Sealing And Construction Joint Sealing
Application Property:
Non-Sag
Product Description

Polyurethane Construction Sealant For Existing Joint Resealing
 
Problem
 
When an existing construction joint develops cracks, detached edges, or missing sealant, covering the affected area can leave the original weak interface in place. If leakage returns, the repair may require another round of removal and installation.
Before resealing, establish whether the old material has failed, whether the substrate remains sound, and whether the exposed joint geometry supports a suitable replacement seal. The visible surface alone may conceal deeper cavities or damaged edges.
 
Cause
 
Old sealant residues, contamination, and weak substrate layers can interfere with adhesion. Unsuitable joint dimensions or movement beyond the selected material’s capability may also contribute to repeated failure.
Where compatibility between old and new materials has not been established, overlaying introduces additional uncertainty at the interface. Replacement should therefore include investigation of the original failure rather than treating every defect as a material replacement task.
 
Solution
 
This one-component polyurethane construction sealant cures through atmospheric moisture and is supplied in 600 mL foil sausages. It requires no on-site mixing of two components.
For repair assessment, remove failed material, inspect the bonding faces, and conduct adhesion trials on representative substrates. Apply a continuous bead using an approved cross-section. The documented 8–35 mm joint width range does not establish the required depth or confirm movement capability for the existing joint.
 
Technical Specifications
 

Parameter

Supplied Information

Relevance to Repair Selection

Product name

Polyurethane construction sealant

Construction and construction joint sealing

Material system

Polyurethane / PU

Forms an elastomer after curing

Components

One-component

No on-site two-component proportioning

Curing method

Moisture-curing at room temperature

Resealed joints require suitable curing arrangements

Joint width

8–35 mm

Remeasure after removal; depth requires separate determination

Elastic recovery

≥80%

Does not establish old-sealant compatibility or movement class

Application property

Non-sag

Helps retain the applied bead shape

Packaging

600 mL foil sausage

Estimate quantities using the repaired joint geometry

 
Application
 
Assess suitability for resealing existing construction joints. After removing old material, inspect edge damage, internal cavities, and residues that could affect the new bond.
Repair unsound substrate areas before sealant installation. Additional sealant cannot restore the strength of a loose or deteriorating joint edge.
 
How It Works
 
Resealing establishes a new, continuous bond between the replacement bead and sound joint faces. If the new material adheres only to a detachable old layer, that layer remains a potential failure point. Cured elasticity does not repair substrate damage.
 
How to Choose
 
Provide the supplier with the previous sealant type, substrate identity, and surface treatment information. Where the old material is unknown, assess compatibility rather than assuming it.
A representative trial section can help evaluate cleaning effectiveness, adhesion, and practical installation conditions before wider application.
 
Application Scenarios
 
Evaluate local replacement or full-length joint renewal. Local repairs require attention to transitions between retained and replacement material. Full renewal requires dimensional checks along the joint rather than relying on one measurement.
 
FAQ
 
Must every trace of old sealant be removed?
Remove failed and loose material. Retaining residues requires confirmed adhesion and compatibility.

When can the repaired joint be inspected?
Follow the required curing conditions and inspection procedure; surface skin formation alone is insufficient.

Related Products
Send An Inquiry