logo

Clear Building Joint Sealant For Window Corner Joints Extrusion Control

Place of Origin: China
Brand Name: YT
Certification: ISO9001, Work safety standardization certificate
Model Number: 338
Minimum Order Quantity: 50 metric tons
Price: Custom Product Production
Packaging Details: Standard Packaging
Delivery Time: Customized production depends on the situation.
Payment Terms: L/C, D/A, D/P, T/T, Western Union
Supply Ability: Custom Product Production
Inquiry Now
Get A Quote
Specifications
Highlight Features

Neutral Cure building joint sealant

,

Window Corner Joints building joint sealant

,

150mL/min sealant construction

Product Name:
338 Multi-Purpose Silicone Sealant
Sealing Method:
Continuous Sealant Layer
Thixotropic Performance Range:
Good Thixotropic Behavior From −40°C To +40°C
Extrusion Test Value:
≥420 ML/min
Skin Formation Time:
Measured 0.5 H
Cure System:
Neutral Cure
Application System:
One-Component Direct Use
Application:
Vertical Window Joints, Frame Perimeters And Façade Sealing
Product Description

Neutral Cure Silicone Sealant for Window Corner Joints: One-Component System for Extrusion Control and Complete Joint Filling

 

Problem | Why Are Window Corner Joints Prone to Underfilling?

 

Corners require a clear change in application direction. If sealant output stops or gun speed changes during the transition, internal voids may form even when the tooled surface appears continuous.

 

Cause | Why Does Extrusion Behavior Matter at Corners?

 

338 has an extrusion requirement of ≥150 mL/min and a measured result of ≥420 mL/min, providing quantitative evidence of material output.

However, this does not guarantee complete corner filling because nozzle size, gun movement, and operator technique also affect the result. When the bead transitions vertically, sag ≤3 mm provides an additional shape-retention reference.

 

Solution | How Should Corner Joints Be Applied?

 

Clean and verify both substrates before application. Maintain sealant output while approaching the corner and change direction smoothly without creating an unnecessary interruption.

A thickness of generally ≥6 mm is recommended as a joint reference. After application, the measured 0.5 h skin-over time can guide tooling. Corners should be checked for pinholes, voids, and discontinuities.

 

Technical Data

 

Property

Data

Corner Relevance

Extrusion Requirement

≥150 mL/min

Specified value

Measured Extrusion

≥420 mL/min

Continuous output reference

Sag

≤3 mm

Vertical transition control

Thickness

Generally ≥6 mm

Thin-section prevention

Skin-Over

Measured 0.5 h

Tooling reference

 

FAQ

 

Does applying extra sealant automatically prevent corner underfilling?
No. Continuous filling and effective substrate contact are more important.

Is ≥420 mL/min the required sealant volume for a corner?
No. It is an extrusion test value, not a prescribed joint volume.

Related Products
Send An Inquiry