logo

White Uv Cure Silicone Adhesive Sealant For Electronics 365nm LED Curing Process

Place of Origin: China
Brand Name: YT
Certification: ISO9001, Work safety standardization certificate
Model Number: Acrylic Adhesive
Inquiry Now
Get A Quote
Specifications
Highlight Features

Electronics uv cure silicone adhesive

,

365nm uv cure silicone adhesive

,

LED Curing acrylic sealant adhesive

Product Name:
365 Nm LED-Curable Adhesive Sealant
Base Resin:
Urethane Acrylate
Curing Method:
Curing Method
Recommended Light Source:
LED, 365 Nm, UVA
Reference Viscosity:
10,000–20,000 Cps At 10 Rpm
PC Bonding Reference:
PC–PC Shear Strength ≥8 MPa
Inspection Feature:
Fluorescent Under UV Light
Intended Use:
Structural Bonding And Sealing Of Plastic Substrates In Industrial And Consumer Electronic Devices
Product Description

One-Component UV-Curable Adhesive Sealant for Electronics—365 nm LED Curing Process
 
Product Positioning and Intended Use
 
This one-component UV-curable adhesive sealant is based on urethane acrylate resin. The supplied document identifies structural bonding and sealing applications in industrial and consumer electronic devices, particularly on plastic substrates.
This article focuses on establishing a curing process using the recommended light source, irradiance and exposure time. It addresses another technical aspect of the same product rather than describing a separate formulation.
 
Problem | Why Check Curing After a 10-Second Exposure?
 
Exposure time is straightforward to set during electronic device assembly, but it cannot independently establish acceptable curing.
Two adhesive layers exposed for 10 seconds may receive different amounts of UV radiation. Directly illuminated areas and shaded locations therefore need separate assessment. A timer confirms exposure duration; it does not confirm the irradiation conditions throughout the joint.
 
Cause | Equipment Settings Do Not Establish Exposure at the Adhesive
 
The document recommends a 365 nm LED source, an irradiance of 500 mW/cm² and an exposure time of 10 seconds. These conditions should be considered together.
Retaining the exposure time while overlooking irradiance or wavelength removes essential context from the recommendation. Lamp distance, substrate transmission and obstruction by surrounding components also need to be recorded during process trials.
This distinction matters when moving from an exposed test specimen to a component with overlapping parts or restricted light access.
 
Solution | Establish Exposure Conditions Around the Actual Bond Line
 
Confirm the source wavelength, then measure and record irradiation conditions at a position representative of the adhesive layer.
Begin trials with the documented recommendations. Record adhesive thickness, lamp distance and component orientation alongside the exposure settings. Examine the thickest deposits and locations with restricted illumination separately, then use representative joint tests to assess the bonding result.
If equipment settings or component geometry change, review the affected conditions rather than assuming that the original exposure remains suitable.
 
Technical Specifications
 

Property

Document Reference Value or Description

Source

Product name

UV-curable adhesive sealant

Document description

Resin system

Urethane acrylate

Parameter table

Components

One-component

Document description

Recommended source

LED, 365 nm, UVA

Parameter table

Recommended irradiance

500 mW/cm²

Parameter table

Recommended exposure time

10 s

Parameter table

Curing depth

>120 μm

Parameter table

Intended use

Structural bonding and sealing of electronic devices, particularly plastic substrates

Document description

 
Application | Plastic Assemblies with Suitable UV Access
 
The document supports electronic device and plastic substrate applications. For a particular joint, confirm whether UV radiation can reach the adhesive.
Overlap edges, corners and areas obstructed by other components require attention. Suitability should be established using the actual assembly geometry.
 
How It Works | Irradiance and Time Define Nominal Exposure
 
At constant irradiance, 500 mW/cm² for 10 seconds corresponds to a nominal radiant exposure of 5 J/cm².
This figure is calculated from the documented settings. It excludes attenuation through the substrate and should not be treated as the exposure received throughout the adhesive or as an established acceptance threshold.
 
FAQ | Can Lower Irradiance Be Offset by Longer Exposure?
 
Do not assume equivalence. Even where the calculated exposure is identical, verify curing and bonding performance again. The document provides no process data establishing that irradiance and time can be exchanged proportionally.

Related Products
Send An Inquiry