logo

WD PUR Woodworking Flat Lamination Hot Glue Stick Hot Melt Adhesives For Bonding

Place of Origin: China
Brand Name: YT
Certification: ISO9001,
Model Number: Hot Helt Adhesives
Inquiry Now
Get A Quote
Specifications
Highlight Features

hot helt adhesives woodworking

,

flat lamination hot glue sticks

,

wd hot glue sticks

Product Name:
WD PUR Hot Melt Adhesive For Woodworking Flat Lamination
Chemistry And Cure:
Reactive Polyurethane Hot Melt Adhesive; Moisture-curing
Melt Viscosity:
15,000±3,000 MPa·s At 120°C; ISO 3219
Open Time:
4±2 Min
Application Temperature:
120–150°C In The Specification Table; 110–150°C In The Operating Instructions; Clarification Required
Peel Force On PVC:
≥40 N/25 Mm
Solids Content:
100%
Application:
Wood Flat Lamination And WPC Board Flat Lamination
Product Description

WD PUR Hot Melt Adhesive for Woodworking Flat Lamination

 

Problem | Why Is Further Testing Needed After Initial Setting?

 

Wood flat lamination requires both suitable processing speed and bond performance after curing. WD provides initial strength after cooling to support subsequent operations. However, the fact that the laminated surfaces hold together does not indicate full cure. Cooling and final curing should be distinguished when assessing heat and water resistance.

 

Cause | Initial Strength and Cured Properties Develop at Different Stages

 

WD uses a moisture-reactive polyurethane hot melt system. Cooling after application helps establish initial positioning, while moisture curing contributes to subsequent property development. The document describes heat and water resistance after full cure. These descriptions should not be applied directly to the adhesive immediately after pressing.

 

Solution | Establish Trial Conditions Around Coating and Pressing

 

Record the substrates, actual application temperature and interval before pressing during selection trials. WD has a melt viscosity of 15,000±3,000 mPa·s at 120°C; the temperature must accompany the quoted value. The stated open time is 4±2 minutes, but the test conditions are unspecified. Confirm the production sequence through lamination trials.

 

Application | Wood and WPC Board Flat Lamination

 

The document identifies wood flat lamination and specifically lists WPC board flat lamination. The stated peel force on PVC of ≥40 N/25 mm can serve as a reference for relevant testing. However, the complete laminated construction is not specified, so the value does not establish suitability for every PVC film and board combination. Specific material combinations require validation.

 

How It Works | Why Does Equipment Sealing Matter?

 

The adhesive cures through a reaction with moisture. The document therefore calls for attention to dispensing equipment sealing and advises against prolonged exposure to air after opening. Adhesive supply arrangements should match the processing sequence to reduce unnecessary open exposure.

 

FAQ | Does Testing After 24 Hours Mean Full Cure Has Been Reached?

 

No. The document recommends testing assembled panels after 24 hours but does not specify a full-cure time. It also gives two application temperature ranges: 110–150°C and 120–150°C. Clarification is required before use. Temperatures above 150°C may deform PVC film.