Quick Link
Quick Contact
Address
No. 1707, Industrial Road, Tangshan Town, Huantai County, Zibo City, Shandong Province
Tel
86-533-17860959591
Our Newsletter
Subscribe to our newsletter for discounts and more.
WD PUR Hot Melt Adhesive for Wood and WPC Board Flat Lamination
Product Overview
WD is a moisture-curing reactive polyurethane hot melt adhesive with 100% solids, primarily intended for woodworking flat lamination, including WPC board flat lamination. It provides initial strength after cooling to support subsequent operations, with heat and water resistance after full cure.
Problem | Why Is Heating Temperature Alone Insufficient for Adhesive Selection?
Woodworking flat lamination requires attention to adhesive application conditions, the temperature limitations of facing materials and subsequent processing requirements. Although WD is applied as a hot melt adhesive, heating capability alone does not establish suitability. Processes involving PVC film must also account for the high-temperature deformation risk identified in the document.
Cause | Application, Measurement and Service Temperatures Have Different Meanings
The stated 120°C is the measurement temperature for melt viscosity, while 85±5°C is the softening temperature. Neither directly establishes the service-temperature range after curing. The document does not specify a continuous heat-resistance temperature, so its description of heat resistance after full cure should not be converted into a temperature-specific service commitment.
Solution | Clarify the Temperature Range Before Establishing the Processing Sequence
The operating instructions state 110–150°C, while the specification table states 120–150°C. The different lower limits require clarification before use. During trials, record the actual application temperature, substrate combination and interval before pressing. Evaluate the processing sequence with reference to the stated open time of 4±2 minutes, rather than directly applying a value with unspecified test conditions to the production line.
Technical Specifications
|
Parameter |
Value or Description |
Conditions and Notes |
|---|---|---|
|
Product Model |
WD |
Model listed in the document |
|
Chemical Composition |
Reactive polyurethane hot melt adhesive |
PUR hot melt system |
|
Curing Mechanism |
Moisture-curing |
Equipment sealing and air exposure require attention |
|
Solids Content |
100% |
Stated value |
|
Color |
Water-white |
Visual inspection |
|
Density |
1.1±0.05 g/cm³ |
Standard listed: GB/T 13477-2002 |
|
Melt Viscosity |
15,000±3,000 mPa·s |
At 120°C; ISO 3219 |
|
Open Time |
4±2 min |
Test conditions not specified |
|
Softening Temperature |
85±5°C |
Does not establish maximum service temperature after curing |
|
Application Temperature |
120–150°C in the specification table; 110–150°C in the operating instructions |
Different lower limits; clarification required |
|
Peel Force on PVC |
≥40 N/25 mm |
Full test conditions not specified |
|
Packaging |
20 kg/drum or 170 kg/drum |
As stated in the document |
|
Storage Conditions |
Cool, dry conditions at 10–25°C |
As stated in the storage instructions |
|
Shelf Life |
6 months in original packaging |
As stated in the document |
Application | Keep the Scope Specific to Woodworking Flat Lamination
The document identifies wood flat lamination and specifically lists WPC board flat lamination. The PVC-related peel-force value can serve as a reference for trials. However, the complete laminated construction is not specified, so it does not establish suitability for every PVC film and board combination or for specific furniture or building components.
How It Works | Initial Setting Must Be Distinguished from Full Cure
WD provides initial strength after cooling to support subsequent processing. Heat and water resistance are described for the fully cured adhesive. The document recommends testing assembled panels after 24 hours, but this period does not establish a full-cure time.
How to Choose | Validate the Actual Material Combination