Quick Link
Quick Contact
Address
No. 1707, Industrial Road, Tangshan Town, Huantai County, Zibo City, Shandong Province
Tel
86-533-17860959591
Our Newsletter
Subscribe to our newsletter for discounts and more.
368 Non-Sag Silicone Sealant for Vertical Window and Building Joints
Problem|Why Are Vertical Joints More Difficult to Seal Evenly?
Vertical joints are common around window frames, glazing edges and connections between building components. Unlike horizontal joints, freshly applied sealant in a vertical joint is continuously affected by gravity before it fully cures.
Excessive sag can change the original bead profile, creating uneven material distribution or local accumulation. For window installation and building sealing, this is not simply an appearance issue because changes in the bead profile may also affect the actual dimensions of the sealed joint.
For this reason, vertical joint sealant selection should consider measurable sag performance rather than relying only on subjective descriptions such as “thick consistency” or “easy vertical application.”
Cause|What Determines Bead Stability on a Vertical Surface?
Vertical bead stability depends on the rheological properties of the sealant as well as application temperature, joint dimensions, dispensing volume and finishing technique.
According to the supplied technical data, 368 Silicone Weatherproof Sealant has a sag value of ≤3 mm, providing a quantitative reference for maintaining the profile of uncured sealant in vertical applications.
However, sag resistance alone is not enough. Poor dispensing continuity can still result in underfilled areas. The specified extrusion rate of ≥150 mL/min provides an additional measurable reference for continuous gun application.
For vertical window joints, sag and extrusion performance should therefore be considered together.
Solution|Control Sag While Maintaining Continuous Application
368 is a one-component, neutral-curing silicone sealant intended for window installation, glazing and general sealing of compatible construction materials.
Its ≤3 mm sag provides a measurable parameter for vertical frame joints, glazing edges and other building joints. The ≥150 mL/min extrusion rate provides additional information for continuous application along longer joints.
The specified tack-free time is ≤3 hours. Tack-free time should not be interpreted as full cure time, and unnecessary disturbance of the joint should be avoided while the sealant continues to cure.
For mechanical properties, the tensile modulus is >0.4 MPa at 23°C and >0.6 MPa at -20°C. The supplied technical information also states no failure in adhesion at maintained extension and no failure after water immersion under the specified test conditions.
The recommended application temperature is 5°C–40°C.
Technical Specifications
|
Property |
Specification |
|---|---|
|
Product Type |
One-Component Neutral Silicone Weatherproof Sealant |
|
Appearance |
Homogeneous Paste |
|
Sag |
≤3 mm |
|
Tack-Free Time |
≤3 h |
|
Extrusion Rate |
≥150 mL/min |
|
Tensile Modulus at 23°C |
>0.4 MPa |
|
Tensile Modulus at -20°C |
>0.6 MPa |
|
Adhesion at Maintained Extension |
No Failure |
|
Adhesion after Water Immersion |
No Failure |
|
Mass Loss |
≤20% |
|
Recommended Application Temperature |
5°C–40°C |
|
Standard |
JC/T 882-2001 |
|
Packaging |
300 mL Cartridge / 590 mL Sausage |
How It Works
Freshly applied sealant has not yet developed its final cured properties. In a vertical joint, the material needs to maintain its applied profile while the curing process progresses.
The specified ≤3 mm sag provides a measurable reference for this vertical application behavior.
However, ≤3 mm sag should not be interpreted as meaning that the material cannot move at all after application. Actual bead stability is also influenced by temperature, joint dimensions, dispensing volume and installation technique.
Continuous filling and proper tooling are therefore important for maintaining a controlled vertical sealant joint.
Application Scenarios
368 can be used for vertical joints along aluminum window frames, door frame perimeter joints, vertical glazing edges, frame-to-cement substrate connections and other compatible vertical building joints.
For window projects, it is particularly relevant to perimeter sections requiring continuous vertical application.
Where a joint is designed to transfer structural loads, product selection should be based on the structural design requirements rather than sag performance alone.