Specifications
Highlight Features

curing epoxy adhesive

,

epoxy adhesive led

,

silver epoxy for ic

Product Name:
One-Component Epoxy Die Attach Adhesive
Material System:
Conductive Silver Epoxy
Component And Cure:
One-component, Heat-curing
Typical Thermal Conductivity:
8 W/(m·K)
Typical Volume Resistivity:
1.0 × 10⁻⁴ Ω·cm
Typical Die Shear At 25°C:
10.2 Kgf; 2 Mm × 2 Mm, Si-Ag
Recommended Curing Schedule:
175°C For 1.0 Hour
Application:
Bonding And Securing Automotive-grade IC And LED Chips
Product Description

One-Component Heat-Curing Conductive Silver Adhesive For IC And LED Dispensing With Defined Thawing And Working-Time Requirements
 
Product Positioning
 
This one-component, heat-curing conductive silver epoxy is intended for bonding and securing automotive-grade IC and LED chips. The document describes no tailing or stringing and low moisture absorption. For dispensing applications, selection should consider rheological data, thawing requirements and the recommended working period together, rather than relying on initial viscosity alone.
 
Specifications
 

Item

Document specification or requirement

Typical value / test conditions

Product system

One-component, heat-curing conductive silver adhesive

Epoxy system

Appearance

Silver

Silver

Viscosity

8,500–11,000 cP

10,000 cP; 5 rpm, spindle No. 51

Thixotropic index

4.0–5.0

4.5; 0.5 rpm / 5 rpm

Thermal conductivity

Approximately 8 W/(m·K)

Typical value: 8 W/(m·K)

Volume resistivity

<2 × 10⁻⁴ Ω·cm

Typical value: 1.0 × 10⁻⁴ Ω·cm; standard curing conditions

Thawing

60–90 minutes at room temperature

Keep the syringe upright

Use after thawing

Recommended use within 36 hours

23°C, 50% RH; no repeated freezing and thawing

Recommended cure

175°C for 1.0 hour

—

Packaging

5 cc or 10 cc

Available according to requirements

Storage and shelf life

Original packaging at ≤−40°C

Six months from manufacture

 
Problem | Does String-Free Dispensing Establish Production Readiness?
 
Chip dispensing requires assessment of adhesive cutoff, shot quantity, placement and adhesive distribution after die placement. Even when a material is described as having no tailing or stringing, equipment trials remain necessary. Thawing and working-time controls must also be included.
 
Cause | One Viscosity Value Cannot Fully Describe Dispensing Behaviour
 
The typical viscosity is 10,000 cP at 5 rpm using spindle No. 51. The typical thixotropic index is 4.5, based on measurements at 0.5 rpm and 5 rpm. These values describe flow characteristics under specified measurement conditions. They cannot directly determine dispensing pressure, needle size or shot quantity.
 
Solution | Organise Material Handling Around Recorded Times
 
After removal from frozen storage, keep the syringe upright and thaw it at room temperature for 60–90 minutes. Use it on the dispensing equipment promptly after thawing. Record removal, thaw completion and start-of-use times. At 23°C and 50% RH, use within the recommended 36-hour period. Repeated freezing and thawing must not be used to extend usability.
 
Application | IC and LED Die Attachment Processes
 
The documented application is attachment of automotive-grade IC and LED chips. Process validation can address material handling, thawing, dispensing or dipping, die placement and heat curing. Needle selection, dispensing patterns and bondline thickness are unspecified and require sample assessment.
 
How to Choose | Match Package Size to Material Consumption
 
Select between 5 cc and 10 cc packaging according to shift consumption and equipment scheduling. The key considerations are whether thawed material can be consumed within the recommended period and whether storage in its original packaging at ≤−40°C is available.
 
FAQ | What Are the Handling and Curing Limits?
 
Does the 36-hour recommendation apply to every production environment?
It applies to 23°C and 50% RH. It should not automatically be transferred to other conditions.

Can the curing time be shortened?
The document recommends 175°C for one hour and provides no alternative schedule. Any adjustment requires validation of curing and bonding results.