Die Attach Adhesive | One-Component Heat-Curing Silver Epoxy for IC and LED Bonding with Die Shear Data at Two Temperatures
Product Positioning
This one-component, heat-curing conductive silver epoxy is intended for bonding and securing automotive-grade IC and LED chips. Die shear data at 25°C and 160°C help purchasing and process teams distinguish room-temperature performance from elevated-temperature results before validating the actual die, substrate and curing process.
Specifications
Item | Document specification | Typical value or test conditions |
|---|---|---|
Material and curing system | One-component, heat-curing conductive silver adhesive | Epoxy system |
Die shear at 25°C | 10.0 kgf | 10.2 kgf; 2 mm × 2 mm, Si-Ag |
Die shear at 160°C | 1.5 kgf | 1.5 kgf; 2 mm × 2 mm, Si-Ag |
Modulus at 25°C | >3 GPa | 4 GPa; dynamic mechanical analysis (DMA) |
Glass transition temperature | 34°C | 34°C; thermomechanical analysis |
Thermal conductivity | Approximately 8 W/(m·K) | 8 W/(m·K); laser flash method |
Volume resistivity | <2 × 10⁻⁴ Ω·cm | 1.0 × 10⁻⁴ Ω·cm; standard curing conditions |
Recommended cure | — | 175°C for 1.0 hour |
Thawing | — | 60–90 minutes at room temperature, syringe upright |
Use after thawing | — | Recommended use within 36 hours at 23°C and 50% RH |
Storage | — | Original packaging at ≤−40°C; six-month shelf life from manufacture |
Problem | Can Room-Temperature Data Establish Attachment Performance at Higher Temperatures?
Room-temperature die shear alone cannot establish bonding performance at elevated temperatures. This product provides results at both 25°C and 160°C. Each should be assessed separately rather than using room-temperature data in place of validation at other temperatures.
Cause | Temperature and Specimen Conditions Affect Comparability
Typical die shear is 10.2 kgf at 25°C and 1.5 kgf at 160°C, both under the stated 2 mm × 2 mm, Si-Ag conditions. Test temperature must remain attached to each value. Results should not be directly extended to different die areas, substrate finishes or continuous operating conditions.
Solution | Include Die Shear Testing in Actual Sample Validation
Record die dimensions, substrate finish, bondline condition and curing programme during trials. Select test temperatures according to project requirements. The recommended cure is 175°C for one hour. Process changes require renewed bonding assessment; the original values should not automatically be assigned to a modified cure.
Application | IC and LED Die Attachment
The documented application is attachment of automotive-grade IC and LED chips. Confirm that the bonding location permits a conductive adhesive and that the components can accommodate the curing temperature. The document does not list every package or surface finish, so specific combinations require trials.
How to Choose | How Should Modulus and Die Shear Be Interpreted?
The typical modulus of 4 GPa at 25°C describes material stiffness under the relevant test conditions. Die shear describes the load response of a specified bonded specimen. These properties are different: higher modulus alone does not establish stronger adhesion or better vibration resistance.
FAQ | How Should Temperature Data Be Read?
Do the results at 160°C establish continuous operation at that temperature?
No. The document provides no exposure duration or aged-performance results for continuous operation at 160°C.
Does a glass transition temperature of 34°C mean failure above that temperature?
No such conclusion can be drawn. Glass transition temperature is not a bonding failure temperature and cannot independently define the service-temperature range.